Wooden facade element production drawing
(Custom ordered Pre-Træ elements)
SW2 TGU vertical cladding 21x120mm
20x45mm distance batten
12x45mm distance strip
Ivarsson Wind panel standard 8mm
45x245 wooden studs with 1000x400x240 Rockwool Murbatts37
DPM
45x45mm counter battens with Rockwool insulation
Gypsum boards 12mm
SW2 TGU vertical cladding 21x120mm
Fire requirement:class R 60 A2-s1, d0
Actual class : [R]EI 60[BD wall 60]
U-value requirement:0.15W/m²K( BR10 7.3.2)
Actual U-value:0.13W/m²K
Presented production drawing of a wooden facade element belongs to a Multi-purpose center situated in Bygholm area in Horsens, Denmark.
Production drawing contains detailed information about assembly process, materials, U-value and fire class.
3D visualized view,as well as plan,elevation and cross-section views were performed in Autodesk Revit 2015.
The main challenge of designing the element was consideration of client's demand of prefabricating the element with cladding, which is very often assembled on-site instead of factory.